The test condition for FUE according to IEC 60950 Annex U voltage:
a) For reinforced insulation used in ITE equipment is to use the appropriate test voltage as specified in the electric strength tests, in the Standard for Information Technology Equipment - Safety - Part 1: General Requirements, UL 60950-1, or 3000 V rms, whichever is greater;
b) For reinforced insulation used in medical equipment is to use the appropriate test voltages as specified in the dielectric strength tests, Standard for Medical Electrical Equipment, Part 1: General Requirements for Safety, UL 60601-1, or 3000 V rms, whichever is greater;
c) For basic or supplementary insulation is to use the appropriate test voltage as specified in the electric strength tests, in UL 60950-1, or 1500 V rms, whichever is greater.
Remark : The Second Edition of IEC 62368-1 has been published in early 2014 and in the next five years this edition will replace the current safety standards for information and communications technology equipment (60950-1) and consumer electronics (60065). Since IEC 62368-1 is a new standard and not a simple merger of IEC 60065 and IEC 60950-1 it is important for manufacturers to prepare for the new standard and its hazard-based and performance-oriented approaches compared to the more prescriptive approach of the existing legacy standards.

- Magnet wire
General characteristic
BCwire® UL listed magnet wire
UL Recognition certificates
Electrical insulation system
Safety considerations
Factory location
- Magnet wire standard
NEMA standard
JIS standard
IEC standard
NEMA Magnet Wire Standards
Cross reference of magnet wire
International standards
Wire gauge conversion table
- FIW
Zero-defect enamelled round copper wire
FIW Technical Values
ICE 60950 Annex U
Dimensions of FIW
Weight per 1km of FIW
Length per 1kg of FIW
- Other technologies
Round copper magnet wire
Flat magnet wire
Packaging guide & Spool Type
Label & Outside Box Marking
Contact Info
Tel:+(0760) 8828 5198
Fax:+(0760) 8828 5008
Eamil : sales@zsiec.cn